An Efficient Control Method of Shunt Active Power Filter Using ADALINE
نویسندگان
چکیده
منابع مشابه
Single-Phase Shunt Active Power Filter Using Indirect Control Method
A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملShunt Active Power Filter Design using Genetic Algorithm Method
-This paper deals with the active power filter design controlled by using hysteresis technique. The genetic algorithm is used to design the controllers to minimize the %THD of the source current. The results are compared with that designed from Ingram and Round approach. The simulation results confirm that the genetic algorithm can provide the minimum %THD of the source current compared with th...
متن کاملPower System Harmonic Compensation Using Shunt Active Power Filter
This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...
متن کاملEfficient Hybrid Shunt Active Power Filter for Improvement of Power Factor and Harmonic Suppression using MATLAB
Power quality management is the main problem that the industry is facing today. This is mainly affected by the generation of harmonics. The growing use of electronic equipment produces a large amount of harmonics in distribution systems because of non-sinusoidal currents consumed by non-linear loads. As we know for the better quality of power, the voltage and current waveforms should be sinusoi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IFAC-PapersOnLine
سال: 2016
ISSN: 2405-8963