An electron Talbot interferometer

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An electron Talbot interferometer

The Talbot effect [1], in which a wave imprinted with transverse periodicity reconstructs itself at regular intervals, is a diffraction phenomenon that occurs in many physical systems. Here we present the first observation of the Talbot effect for electron de Broglie waves behind a nanofabricated transmission grating. This was thought to be difficult because of Coulomb interactions between elec...

متن کامل

Temporal impulse response of the Talbot interferometer

The Talbot interferometer has been shown earlier to act as an optical tapped delay-line in the time domain. The interferometer is based on the self-imaging effect. It consists of two gratings separated by a multiple of the self-imaging distance. Here, we determine its temporal behaviour experimentally. First, the impulse response is measured directly in the time domain by means of femtosecond p...

متن کامل

Phase Imaging with an X-ray Talbot Interferometer

X-ray Talbot interferometry (XTI) is described as a novel phase-sensitive X-ray imaging method. XTI uses two transmission gratings, and therefore in principle it functions with cone-beam X-rays of a broad energy band width, allowing its instrumentation with a compact X-ray source. Because an amplitude transmission grating is needed, X-ray lithography and electrochemical gold plating were employ...

متن کامل

A Kapitza–Dirac–Talbot–Lau interferometer for highly polarizable molecules

STEFAN GERLICH1, LUCIA HACKERMÜLLER1*, KLAUS HORNBERGER2, ALEXANDER STIBOR1, HENDRIK ULBRICHT1, MICHAEL GRING1, FABIENNE GOLDFARB1‡, TIM SAVAS3, MARCEL MÜRI4, MARCEL MAYOR4,5 AND MARKUS ARNDT1 Faculty of Physics, University of Vienna, Boltzmanngasse 5, A-1090 Wien, Austria Arnold Sommerfeld Center for Theoretical Physics, Ludwig-Maximilians-Universität München, Theresienstrasse 37, 80333 Münche...

متن کامل

Optimal Design of Transmission Grating for X-ray Talbot Interferometer

How to maximize the efficiency of X-ray Talbot interferometry (XTI) is discussed for X-ray phase imaging. Shape parameters of an amplitude grating used in XTI strongly affect the efficiency. We calculated efficiencies assuming rectangular and trapezoidal patterns for an absorption grating. As a result, a rectangular absorption grating of a duty ratio of 1:1 is optimal. But, a trapezoidal patter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: New Journal of Physics

سال: 2009

ISSN: 1367-2630

DOI: 10.1088/1367-2630/11/3/033021