An Energy Graph-Based Approach to Fault Diagnosis of a Transcritical CO2 Heat Pump
نویسندگان
چکیده
منابع مشابه
An LPV Approach to Sensor Fault Diagnosis of Robotic Arm
One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...
متن کاملOptimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications
Energetic and exergetic analyses as well as optimization studies of a transcritical carbon dioxide heat pump system are presented in this article. A computer code has been developed to obtain sub-critical and super-critical thermodynamic and transport properties of carbon dioxide. Estimates for irreversibilities of individual components of the system lead to possible measures for performance im...
متن کاملPerformance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating
This paper presents the experimental as well as the simulated performance studies on the transcritical CO2 heat pumps for simultaneous water cooling and heating; effects of water mass flow rates and water inlet temperatures of both evaporator and gas cooler on the cooling and heating capacities, system COP and water outlets temperatures are investigated. Study shows that both the water mass flo...
متن کاملExperimental investigation on the influencing factors of a transcritical CO2 heat pump
As one of the earliest natural refrigerants, CO2 has a lot of unique advantages, such as zero ODP, negligible GWP, excellent heat transfer coefficient, high volumetric capacity, non-toxicity, non-flammability, and cost effectiveness. Since it was proposed to applying in the mobile air-conditioning, the transcritical CO2 cycle has been attracting great attentions to replace CFC and HCFC refriger...
متن کاملTranscritical Co2 Mobile Heat Pump and A/c System Experimental and Model Results
This article presents the results of the experimental runs of a prototype of R744 (CO2) refrigeration system operating in a both air conditioning and heat pump mode when heat rejection is done in supercritical region. The prototype system is sized for a compact car. Data presented are in the limited range of operation. Further optimization and extension of operating range is underway. Test faci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2020
ISSN: 1996-1073
DOI: 10.3390/en13071783