An Extended System Frequency Response Model Considering Wind Power Participation in Frequency Regulation
نویسندگان
چکیده
منابع مشابه
An Extended System Frequency Response Model Considering Wind Power Participation in Frequency Regulation
With increasing penetration of wind power into the power system, wind power participation in frequency regulation is regarded as a beneficial strategy to improve the dynamic frequency response characteristics of power systems. The traditional power system frequency response (SFR) model, which only includes synchronous generators, is no longer suitable for power systems with high penetrated wind...
متن کاملImpacts of High Wind Power Penetration on the Frequency Response Considering Wind Power Reserve
With high wind power penetration, imbalance between generation and consumption is increased, and as a consequence the frequency deviation from the nominal value will be magnified. For frequency control purpose in conventional power systems, the synchronous generators are only responsible. However, it is expected that the renewable energy sources (RESs) are also needed to contribute in frequency...
متن کاملActive Participation of Air Conditioners in Power System Frequency Control Considering Users’ Thermal Comfort
Air conditioners have great potential to participate in power system frequency control. This paper proposes a control strategy to facilitate the active participation of air conditioners. For each air conditioner, a decentralized control law is designed to adjust its temperature set point in response to the system frequency deviation. The decentralized control law accounts for the user’s thermal...
متن کاملAn Optimal Dispatch Model of Wind-Integrated Power System Considering Demand Response and Reliability
Demand response (DR) has become an impressive option in the deregulated power system due to its features of availability, quickness and applicability. In this paper, a novel economic dispatch model integrated with wind power is proposed, where incentive-based DR and reliability measures are taken into account. Compared with the conventional models, the proposed model considers customers’ power ...
متن کاملModern power system frequency response evaluation with virtual power plant penetration
New power systems based on VPP will be expanded in the future and analysis of the frequency behavior of these systems compared to current systems in the field of disruptions will be one of the most important issues of the system operators. In this paper, the equations of the frequency response model of conventional power system are expanded by considering the VPP's and their effective component...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2017
ISSN: 1996-1073
DOI: 10.3390/en10111797