An Improved Electromagnetic Flowmeter
نویسندگان
چکیده
منابع مشابه
An electromagnetic catheter-flowmeter.
An electromagnetic flowmeter incorporated into a catheter is described. The catheter is introduced into the aorta via the femoral artery. The flow sensor is located some distance below the catheter tip and is sensitive to flow at right angles to the catheter. A crater-like elevation at one end of the transducer lumen permits funnel-like connection of the transducer to the ostium of an aortic br...
متن کاملDynamic Synchronous Capture Algorithm for an Electromagnetic Flowmeter
This paper proposes a dynamic synchronous capture (DSC) algorithm to calculate the flow rate for an electromagnetic flowmeter. The characteristics of the DSC algorithm can accurately calculate the flow rate signal and efficiently convert an analog signal to upgrade the execution performance of a microcontroller unit (MCU). Furthermore, it can reduce interference from abnormal noise. It is extre...
متن کاملAnalog signal processing in an AC electromagnetic flowmeter
AC electromagnetic flowmeters yield a low-frequency signal whose amplitude is proportional to the average fluid velocity. Typically, the input signal magnitude is below 1 mV and suffers a strong electric and magnetic interference from the coils that create the driving magnetic field. This paper provides a novel circuit design to amplify and demodulate the voltage picked up by the electrodes and...
متن کاملA Transient Electromagnetic Flowmeter and Calibration Facility
Flowmeter and Calibration Facility P.J. Lefebvre Naval Underwater Systems Center, Newport, R.1. An electromagnetic flowmeter was developed to measure transient flows at a data rate of 60 Hz. The approach taken was to develop suitable electronics to replace the electronics ofa commercially available electromagnetic flowmeter normally used W. W. Durgin for steady-state operation. Use of the comme...
متن کاملEffect of hematocrit value upon electromagnetic flowmeter sensitivity.
An electromagnetic flowmeter system that has an accuracy of 0.1% and is insensitive to fluid conductivity was used to study the sensitivity to steady flow of a 6-mm cannular transducer. All measurements were carried out at 37°C. Sensitivity decreased with increasing hematocrit value whether flow was laminar or otherwise. With laminar flow and a given hematocrit value, the sensitivity also decre...