An Improved Entity Similarity Measurement Method
نویسندگان
چکیده
منابع مشابه
Affordance-Based Similarity Measurement for Entity Types
When interacting with the environment subjects tend to classify entities with respect to the functionalities they offer for solving specific tasks. The theory of affordances accounts for this agent-environment interaction, while similarity allows for measuring resemblances among entities and entity types. Most similarity measures separate the similarity estimations from the context—the agents, ...
متن کاملSea Ice Detection Based on an Improved Similarity Measurement Method Using Hyperspectral Data
Hyperspectral remote sensing technology can acquire nearly continuous spectrum information and rich sea ice image information, thus providing an important means of sea ice detection. However, the correlation and redundancy among hyperspectral bands reduce the accuracy of traditional sea ice detection methods. Based on the spectral characteristics of sea ice, this study presents an improved simi...
متن کاملTrust Evaluation using an Improved Context Similarity Measurement
In context-aware trust evaluation, using ontology tree is a popular approach to represent the relation between contexts. Usually, similarity between two contexts is computed using these trees. Therefore, the performance of trust evaluation highly depends on the quality of ontology trees. Fairness or granularity consistency is one of the major limitations affecting the quality of ontology tree. ...
متن کاملAn improved method of in vivo wound disruption and measurement.
Biomechanical studies of wound strength are important because of new investigations in growth factors, cytokines, and fetal wounds. We compared two traditional methods of wound disruption measurement with a novel computerized model designed for in vivo experiments. An Instron tensiometer (INSTS) and an air insufflated positive pressure device (AIPPD) were compared with a vacuum-controlled wound...
متن کاملMeasurement of Bone Mineral in Vivo: an Improved Method.
The mineral content of bone can be determined by measuring the absorption by bone of a monochromatic, low-energy photon beam which originates in a radioactive source (iodine-125 at 27.3 kev or americium 241 at 59.6 kev). The intensity of the beam transmitted by the bone is measured by counting with a scintillation detector. Since the photon source and detector are well collimated, errors result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TELKOMNIKA (Telecommunication Computing Electronics and Control)
سال: 2014
ISSN: 2302-9293,1693-6930
DOI: 10.12928/telkomnika.v12i4.434