An improved low-computation model predictive direct power control strategy for three-level four-leg active power filter

نویسندگان

چکیده

Model predictive direct power control (MPDPC) strategy offers numerous benefits over the traditional strategies in active filters (APF). However, real-time execution duration (RTED) reduction of model multilevel inverters is a big challenge. In this paper, an improved low-computation for three-level four-leg APF (TL-FL-APF) presented. First, based on generalized instantaneous reactive theory, new TL-FL-APF established. Then, order to reduce RTED, classical multiple predictions are converted into single voltage prediction through principle deadbeat control, and optimized vector range reduced from 81 4–18 by method spatial stratification using γ-component reference vector. Finally, simulation experimental results demonstrate that proposed MPDPC has excellent performance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid direct power/current control using feedback linearization of three-level four-leg voltage source shunt active power filter

Introduction The excessive use of power electronic equipments, which represent nonlinear loads, in a distribution network has caused many disturbances in the quality of power such as harmonic pollutions, unbalanced load currents, and reactive power problems. As a result poor power factor, weakening efficiency, overheating of motors and transformers, malfunction of sensitive devices etc. are enc...

متن کامل

Comparison of Current Control Strategies for Three- level Four-leg Shunt Active Power Filter

This paper presents a comparison of two control strategies for 3-level 4-leg Shunt Active Power Filter (SAPF). The first method is based on hysteresis controllers. The second, proposed method is the Model Predictive Control (MPC) with a finite control-states set (FS) based on phase-to-phase model. The two methods are described and simulation results are presented and analyzed. Comparison is per...

متن کامل

An Improved Hybrid Active Power Filter for Power Quality Improvement in Three Phase Four Wire System

This paper presents a hybrid active power filter for a three phase four wire distribution system. The scheme consists of a zigzag transformer, single phase active power filter connected in series with the utility neutral and a coupling capacitor connected in series with a voltage source converter of the active power filter (APF). The addition of coupling capacitor permits the reduction in DC li...

متن کامل

Constrained Model Predictive Control of Low-power Industrial Gas Turbine

Nowadays, extensive research has been conducted for gas turbine engines control due to growing importance of gas turbine engines for different industries and the need to design a suitable control system for a gas turbine as the heart of the industry. In order to design gas turbine control system, various control variables can be used, but in the meantime, fuel flow inserting into combustion cha...

متن کامل

Improved Fully Differential Low Power Active Filter

Received Jan 2, 2017 Revised Mar 2, 2017 Accepted Mar 16, 2017 This paper relates the new topology and simulations of a fully differential CMOS active filter for mm wave band applications. The advantages of the differential topology over the single ended one are discussed and the quality factor is tuned to insure application requirements, including narrow bandwidth and high selectivity due to a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electrical Engineering

سال: 2023

ISSN: ['0948-7921', '1432-0487']

DOI: https://doi.org/10.1007/s00202-023-01818-2