Analisys And Implementation Of Hybrid Active Power Filter
نویسندگان
چکیده
منابع مشابه
Design and Implementation of Hybrid Active Power Filter
This paper deals with a hybrid active power filter with injection circuit (IHAPF). This paper concluded that the stability of the IHAPF based on detection supply current is superior to that of others. To minimize the capacity of IHAPF, an adaptive fuzzy dividing frequency-control method,.The generalized integrator is used for dividing frequency integral control, while fuzzy arithmetic is used f...
متن کاملDesign and Implementation of Hybrid Active Power Filter
This paper deals with a hybrid active power filter with injection circuit (IHAPF). This paper concluded that the stability of the IHAPF based on detection supply current is superior to that of others. To minimize the capacity of IHAPF, an adaptive fuzzy dividing frequency-control method,.The generalized integrator is used for dividing frequency integral control, while fuzzy arithmetic is used f...
متن کاملGenetic Algorithm- Based Active Power Filter Allocation and Size Determination
In this paper, two algorithms have been developed for allocation and size determination of Active Power Filters (APF) in power systems. In the first algorithm, the objective is to minimize harmonic voltage distortion. The objective in the second algorithm is to minimize the new APF injection currents while satisfying harmonic standards. Genetic algorithm is proposed for these two optimization p...
متن کاملGenetic Algorithm- Based Active Power Filter Allocation and Size Determination
In this paper, two algorithms have been developed for allocation and size determination of Active Power Filters (APF) in power systems. In the first algorithm, the objective is to minimize harmonic voltage distortion. The objective in the second algorithm is to minimize the new APF injection currents while satisfying harmonic standards. Genetic algorithm is proposed for these two optimization p...
متن کاملModelling of Three-phase Shunt Hybrid Active Power Filter
The three-phase Shunt hybrid APF topology for harmonic mitigation in low and medium voltage power distribution systems consists of a VSI based three phase shunt active filter (SAF) and tuned passive filters (TPF) connected in parallel with the load. This chapter discusses the modelling of shunt active filter and design of filter interfacing inductor, DC bus capacitor, tuned passive filters. It ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eletrônica de Potência
سال: 2012
ISSN: 1414-8862,1984-557X
DOI: 10.18618/rep.2012.3.575583