Analysis of a Multiple Supply Voltage Floorplan Considering Voltage Drop and Electron Migration Risk
نویسندگان
چکیده
منابع مشابه
Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملSuccessive Pad Assignment for Minimizing Supply Voltage Drop
An efficient pad assignment methodology to minimize voltage drop on a power distribution network is proposed. A combination of successive pad assignment (SPA) with incremental matrix inversion (IMI) determines both location and number of power supply pads to satisfy drop voltage constraint. The SPA creates an equivalent resistance matrix which preserves both pad candidates and power consumption...
متن کاملReactive Power Pricing in an Open Access Environment Considering Combined Optimum Voltage Profile and Voltage Stability
In a de-regulated open access environment, reactive power is one of the ancillary services which must be provided by an Independent System Operator (ISO). In this paper, a new algorithm is proposed in which reactive power resources are initially so tuned that optimum security in terms of voltage profile and voltage stability are achieved while at the same time, the system losses are minimized. ...
متن کاملReactive Power Pricing in an Open Access Environment Considering Combined Optimum Voltage Profile and Voltage Stability
In a de-regulated open access environment, reactive power is one of the ancillary services which must be provided by an Independent System Operator (ISO). In this paper, a new algorithm is proposed in which reactive power resources are initially so tuned that optimum security in terms of voltage profile and voltage stability are achieved while at the same time, the system losses are minimized. ...
متن کاملOptimized Fuzzy Controller Design in Unbalanced Voltage Drop Mode for Dynamic Voltage Restorer
The loss of balanced voltages involves a voltage drop due to symmetric three-phase errors, or the initiation of high-power three-phase loads or symmetric three-phase switches. While these events in an unbalanced way lead to asymmetric voltage drops. Voltage drops can cause asymmetric load on the power grid, the occurrence of volatility, and even network power outage. One of the most common ways...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Engineering & Technology
سال: 2018
ISSN: 2227-524X
DOI: 10.14419/ijet.v7i2.24.12145