Analysis of Implantable Defibrillator Longevity Under Clinical Circumstances: Implications for Device Selection
نویسندگان
چکیده
منابع مشابه
Analysis of implantable defibrillator longevity under clinical circumstances: implications for device selection.
INTRODUCTION Information about implantable cardioverter-defibrillator (ICD) longevity is mostly calculated from measurements under ideal laboratory conditions. However, little information about longevity under clinical circumstances is available. This survey gives an overview on ICD service times and generator replacements in a cohort of consecutive ICD patients. METHODS Indications for repla...
متن کاملLongevity of Sprint Fidelis implantable cardioverter-defibrillator leads and risk factors for failure: implications for patient management.
BACKGROUND Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest that certain patients are at increase...
متن کاملArrhythmia/Electrophysiology Longevity of Sprint Fidelis Implantable Cardioverter- Defibrillator Leads and Risk Factors for Failure Implications for Patient Management
Background—Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest that certain patients are at increase...
متن کاملTransvenous Implantable Cardioverter-Defibrillator Lead Reliability: Implications for Postmarket Surveillance
BACKGROUND As implantable cardioverter-defibrillator technology evolves, clinicians and patients need reliable performance data on current transvenous implantable cardioverter-defibrillator systems. In addition, real-world reliability data could inform postmarket surveillance strategies directed by regulators and manufacturers. METHODS AND RESULTS We evaluated Medtronic Sprint Quattro, Boston...
متن کاملIrregular ventricular tachycardia underdetected by implantable cardioverter defibrillator device.
A case of sustained monomorphic ventricular tachycardia underdetected by a single chamber implantable cardioverter defibrillator because of RR interval irregularity is presented. The programmed stability criterion is responsible for the underdetection. Special attention must be paid when it comes to programming this detection parameter.