Analysis of Non-Standard Lightning Impulse Voltage for Actual Substation and Generation Circuit.
نویسندگان
چکیده
منابع مشابه
SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress
In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...
متن کاملCharacterisation at Low Voltage of Two Reference Lightning Impulse Dividers
An effort is pursued by several European National Measurement Institutes to lower the uncertainties in calibration of UHV measuring systems for lighting impulse. To this end, several reference dividers are investigated as regards their accuracy both for amplitude and for time parameters. At SP RISE Research Institutes of Sweden, a 500 kV resistive reference divider has been in use since 2000. A...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولLightning Impulse Ageing of Hdpe
This work is concerned with the hypothesis that lightning impulses can lead to accelerated ageing of extruded polymeric cables. The behaviour of an insulation material when suffering lightning impulses is different from that for DC or power frequency over-voltages. Shaped HDPE material samples have been manufactured using a mould tool. The samples then may be electrically aged using one of the ...
متن کاملComparative Reliability Analysis of Substation Automation Architecture Based on IEC 61850 Standard
Using IEC 61850 standard would increase the reliability and availability of electricity network and put a huge impact on network automation. Even though much research works has been done in substation system reliability, there is a few works in automated substation control system reliability. This paper evaluates the reliability of substation automation system based IEC 61850 comparatively cons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 2003
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes.123.175