Analytic design of multiple-axis, multifocal diffractive lenses
نویسندگان
چکیده
منابع مشابه
Analytic design of multiple-axis, multifocal diffractive lenses.
In this Letter, we introduce an analytic procedure for designing diffractive lenses using the combination of wavefronts aberrated by Zernike polynomials. We show how to design amplitude-only, phase-only, continuous, and binary lenses providing equivalent results. As an example we apply it to the design of a multiple-axis, multifocal lens. The number of foci and their positions can be easily con...
متن کاملBilateral implantation of asymmetrical diffractive multifocal intraocular lenses.
OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...
متن کاملEnergy balance in apodized diffractive multifocal intraocular lenses
The energy distribution between the distance and near images formed in a model eye by three different apodized diffractive multifocal intraocular lenses (IOLs) is experimentally determined in an optical bench. The model eye has an artificial cornea with positive spherical aberration (SA) similar to human cornea. The level of SA upon the IOL, which is pupil size dependent, is controlled using a ...
متن کاملStraylight Measurements in Two Different Apodized Diffractive Multifocal Intraocular Lenses.
PURPOSE To evaluate differences in straylight between eyes implanted with a hydrophilic multifocal IOL (Seelens MF; Hanita Lenses, Hanita, Israel) and a hydrophobic multifocal IOL (SN6AD1; Alcon Laboratories, Inc., Fort Worth, TX). METHODS In a prospective cohort study, routinely obtained straylight measurements (C-Quant; Oculus Optikgeräte, Wetzlar, Germany) 3 months after standard phacoemul...
متن کاملOptical metrology for immersed diffractive multifocal ophthalmic intracorneal lenses
P. Tankam Laboratoire Hubert Curien (UMR 5516 CNRS), Université de Lyon, Université Jean-Monnet, 42000, Saint-Etienne, France T. Lépine [email protected] Laboratoire Hubert Curien (UMR 5516 CNRS), Université de Lyon, Université Jean-Monnet, 42000, Saint-Etienne, France Institut d’Optique Rhône-Alpes 18 rue Benoı̂t Lauras 42000, Saint-Etienne, France F. Castignoles Presbeasy, Lyon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Letters
سال: 2012
ISSN: 0146-9592,1539-4794
DOI: 10.1364/ol.37.001121