Analytical approach to noncircular section birdcage coil design: Verification with a Cassinian oval coil

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B1 field homogeneity and SAR calculations for the birdcage coil.

The finite-difference time-domain (FDTD) method is used to model a birdcage resonator. All the coil components, including the wires, lumped capacitors and the source, are geometrically modelled together. As such, the coupling effects within the birdcage, including the interactions of coil, source and human head, are accurately computed. A study of the transverse magnetic (B1) field homogeneity ...

متن کامل

RF Field Mapping of a High Field (3T) Birdcage Coil

INTRODUCTION Birdcage coils [l] are widely used for MRI studies of the human brain. Since anatomical constraints require a short birdcage coil (less than 35 cm), the RF field Bi inhomogeneities along the coil axis can be a limiting factor for image quality. Moreover, at high field (23T) numerical MRI results [2-31 show that the Bi is degraded because of strong interactions (inductive sample los...

متن کامل

Numerical Comparison Between TEM Head Coil and Birdcage Head Coil at 7T

G. D. DeMeester, Z. Zhai, M. A. Morich, C. Leussler, C. Findeklee Philips Medical Systems, Cleveland, Ohio, United States, Philips Research Laboratories, Hamburg, Hamburg, Germany Introduction A TEM T/R head coil and a shielded birdcage T/R head coil operated at 298MHz/7T were both modeled using the Finite Difference Time Domain (FDTD) method. The two coils have approximately the same physical ...

متن کامل

Quadrature Lowpass Birdcage Coil for Low Field Open Mri Scanner

The main goal of this research was to demonstrate the utility of using a quadrature birdcage coil in lowpass version for magnetic resonance imaging (MRI) in open scanner at very low static field. When used in horizontal bore MRI systems, the birdcage coil is able to produce circular polarized field using quadrature excitation, thus reaching SNR improvement of 2 as maximum value. The birdcage co...

متن کامل

Design and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T

This work describes the study of coil for Magnetic Resonance Imaging (MRI) application. Concretely, the principal objective is the design of a birdcage coil (RF coil) to use in a 7 Tesla scanner. More strength field has a better SNR and increased chemical shift effects, improving spectral fat suppression and spectroscopy. Moreover, a better SNR increases the spatial resolution or reduces the im...

متن کامل