Analytical Nonlinear Reluctance Model of a Single-Phase Saturated Core Fault Current Limiter
نویسندگان
چکیده
منابع مشابه
Single-Phase Resistive Superconductor Electrical Current Limiter
This paper presents the analysis, design, construction and ac test results of low voltage single-phase resistive superconductor electrical current limiters. Two different types of resistive superconductor current limiter are presented: the first one is built with three concentric, cylindrical and helicoidal coils connected in parallel and the second one is built with two superposed cylindrical ...
متن کاملStudy of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملFinite element modeling of a superconducting fault current limiter
This paper summarizes the work done to show finite element modeling results on a high temperature superconductor fault current limiter (FCL). The paper also gives the small mock-up design of the matrix FCL and its finite element model (FEM). It also discusses the limitations of the FEM and explains how the results from the FEM compare with the experimental data derived for the configuration. A ...
متن کاملFault Current Limiter for a Distributed Power System
The up-gradation of an Electrical power generation network results in higher levels of short circuit fault current. Thereby, the existing protection equipment like circuit breakers, isolators and fuses become under capacity and not capable of withstanding higher short circuit currents. Thus the system is highly vulnerable to the adverse effects of short circuits. Replacing the whole protection ...
متن کاملA comprehensive overview, behavioral model and simulation of a Fault Current Limiter
Distribution systems across most parts of the globe are highly radial in nature. As loads are gradually increased on a particular distribution system, a higher operating current state leading to increased fault current levels is attained. Hence, the relay co-ordination is disturbed and equipments such as feeders and circuit breakers need to be replaced with higher rating so that they can handle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Power Delivery
سال: 2013
ISSN: 0885-8977,1937-4208