Anatomic Augmented Glenoid Implants for the Management of the B2 Glenoid
نویسندگان
چکیده
منابع مشابه
Arthroscopic Anatomic Glenoid Reconstruction: Analysis of the Learning Curve
This open‐access article is published and distributed under the Creative Commons Attribution ‐ NonCommercial ‐ No Derivatives License (http://creativecommons.org/licenses/by‐nc‐nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article w...
متن کاملAnatomic osteochondral glenoid reconstruction for recurrent glenohumeral instability with glenoid deficiency using a distal tibia allograft.
The treatment of glenoid bone loss in the setting of recurrent shoulder instability remains a challenge. This is because of the nonanatomic nature and resultant incongruous joint resulting from most bony augmentation procedures. We present a novel technique for the management of glenoid bone deficiency by using a fresh osteochondral distal tibial allograft. We have found that the distal tibia h...
متن کاملQuantification of B2 glenoid morphology in total shoulder arthroplasty.
BACKGROUND B2 glenoid morphology is challenging to address with shoulder reconstruction. Deformity often renders current techniques inadequate, necessitating compromises that limit long-term implant durability. The purpose of this study was to perform in vivo measurements of glenoid deformity to better appreciate the orientation of the B2 biconcavity demarcation and erosion that surgeons face i...
متن کاملAddressing glenoid erosion in anatomic total shoulder arthroplasty.
Glenoid wear is common in the setting of shoulder arthritis. Severe glenoid erosion presents a serious challenge to the surgeon performing a shoulder arthroplasty. This paper presents the various classification schemes for glenoid erosion. The results of the six main treatment options for shoulder arthroplasty with an eroded glenoid are reviewed. The six treatment options include: 1. eccentric ...
متن کاملAcute Failure of a Glenoid Component in Anatomic Shoulder Arthroplasty
Glenoid loosening is the most common cause of failure in primary total shoulder arthroplasty (TSA) and often occurs years after the initial surgery. It is rare for a glenoid component to fail acutely. Several case reports of complete glenoid dissociation appear in the literature. It is important to report these failures to identify technical errors or component design flaws to improve outcomes ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Shoulder and Elbow Arthroplasty
سال: 2019
ISSN: 2471-5492,2471-5492
DOI: 10.1177/2471549219870350