ANFIS control of a shunt active filter based with a five-level NPC inverter to improve power quality

نویسندگان

چکیده

This paper addresses the problem of power quality, and degradation current waveform in distribution network which results directly from proliferation nonlinear loads. We propose to use a five-level neutral point clamped (NPC) inverter topology for implementation shunt active filter (SAPF). The aim SAPF is inject harmonic currents phase opposition at connection point. identification harmonics based on pq method. A neuro-fuzzy controller ANFIS (adaptive neuro fuzzy inference system) designed SAPF. simulation study carried out using MATLAB/Simulink show significant improvement quality energy reduction total distortion (THD) accordance with IEC standard, IEEE-519, 61000, EN 50160.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PV Based Three-Level NPC Shunt Active Power Filter with Extended Reference Current Generation Method

This paper proposes an extended reference current calculation method for the PV based three-level neutral point clamped (NPC) shunt active power filter (SAPF). Shunt active power filter demands a source of energy for compensating the current based distortions, which utilizes the photovoltaic array with DC-DC boost converter as a source of DC power. The shunt connected inverter controls the DC l...

متن کامل

Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

متن کامل

Three Level Inverter Based Shunt Active Power Filter Using Multi-Level Hysteresis Band Current Controller

In this paper, a three-level inverter based Shunt Active Power Filter (SAPF) using Multi-Level Hysteresis Current Controller (MLHCC) is presented for solution of power quality problems in distribution system. A simulation model of SAPF is prepared in Matlab/Simulink environment. MLHCC is used for control of SAPF currents. In simulation study, it is considered that SAPF executes two tasks coveri...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

Power quality enhancement using cascaded multilevel inverter based shunt hybrid active power filter

This paper investigates mitigation of current harmonics using different configuration of cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) and to improve power quality of the system. The main objective of this paper is to develop and analyze the compensation characteristics of cascaded multilevel inverter based shunt hybrid active power filter by employing indirect cur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Power Electronics and Drive Systems

سال: 2021

ISSN: ['2722-2578', '2722-256X']

DOI: https://doi.org/10.11591/ijece.v11i3.pp1886-1893