Angle measurement with laser feedback instrument
نویسندگان
چکیده
منابع مشابه
Measurement of craniovertebral angle with Electronic Head Posture Instrument: Criterion validity.
This study evaluated the criterion-related validity of the Electronic Head Posture Instrument (EHPI) in measuring the craniovertebral (CV) angle by correlating the measurements of CV angle with anterior head translation (AHT) in lateral cervical radiographs. It also investigated the correlation of AHT and CV angle with the Chinese version of the Northwick Park Questionnaire (NPQ) and Numeric Pa...
متن کاملMonetary Policy with Single Instrument Feedback Rules .
We revisit the issue of multiplicity of equilibria when monetary policy is conducted with either the interest rate or the money supply as the sole instrument of policy. We show that in standard monetary models there are interest rate feedback rules, and also money supply rules, that implement a unique global equilibrium. This is a contribution to a literature that either concentrates on conditi...
متن کاملLaser confocal feedback tomography and nano-step height measurement
A promising method for tomography and step height measurement is proposed, which combines the high sensitivity of the frequency-shifted feedback laser and the axial positioning ability of confocal microscopy. By demodulating the feedback-induced intensity modulation signals, the obtained amplitude and phase information are used to respectively determine the coarse and fine measurement of the sa...
متن کاملEffect of Cooling on Bending Angle and Microstructure in Laser Tube Bending with Circumferential Scanning
Laser tube bending is a flexible forming process. Two irradiation methods of axial and circumferential scanning are generally used to form metal tubes. The two most important disadvantages of circumferential scanning are its lower bending angle and the time interval required between each scan for cooling purpose. In this research, a novel cooling strategy during laser tube bending with circumfe...
متن کاملMeasurement of changes in optical path length and reflectivity with phase-shifting laser feedback interferometry.
The operating characteristics of a novel phase-shifting interferometer are presented. Interference arises by reflecting the light from a sample back into the cavity of a cw He-Ne laser. Changes in phase and fringe visibility are calculated from an overdetermined set of phase-shifted intensity measurements with the phase shifts being introduced with an electro-optic modulator. The interferometer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2013
ISSN: 1094-4087
DOI: 10.1364/oe.21.008044