Aortic input impedance in heart failure.
نویسندگان
چکیده
منابع مشابه
Aortic input impedance in heart failure.
The input impedance of the systemic circulation was calculated from recordings of pulsatile pressure and flow in the ascending aorta of 20 patients. Ten patients had clinical and hemodynamic evidence of heart failure. The other 10 subjects had no clinical evidence of heart failure and were used as a control group. In the heart failure patients, both input resistance and characteristic impedance...
متن کاملAortic input impedance in infants and children.
Flow and pressure measurements were performed in the ascending aortas of six pediatric patients ranging in age from 1 to 4 yr and in weight from 7.2 to 16.4 kg. From these measurements, input impedance was calculated. It was found that total vascular resistance decreased with increasing patient weight and was approximately one to three times higher than those of adults. Conductance per unit wei...
متن کاملAortic Input Impedance during Nitroprusside Infusion
Receivedfor publication 21 November 1977 and in revised form 16 April 1979. vascular load and improve ventricular function independent of aortic pressure reduction.
متن کاملA novel servo-control system that imposes desired aortic input impedance on in situ rat heart.
To clarify the pathophysiological role of dynamic arterial properties in cardiovascular diseases, we attempted to develop a new control system that imposes desired aortic impedance on in situ rat left ventricle. In 38 anesthetized open-chest rats, ascending aortic pressure and flow waveforms were continuously sampled (1,000 Hz). Desired flow waveforms were calculated from measured aortic pressu...
متن کاملAortic input impedance in man: acute response to vasodilator drugs.
In 18 patients who underwent coronary arteriography, aortic velocity and pressure data were obtained during a control state and during either isoproterenol infusion at 1, 2 and 3 micrograms/min or graded nitroprusside infusion (average peak dose 60 micrograms/min). Impedance moduli and phase angles were derived to 10 Hz for controls states, isoproterenol at 2 micrograms/min, and at peak nitropr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Circulation
سال: 1978
ISSN: 0009-7322,1524-4539
DOI: 10.1161/01.cir.58.3.460