Application of Average Adult Japanese Voxel Phantoms to Evaluation of Photon Specific Absorbed Fractions
نویسندگان
چکیده
منابع مشابه
Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...
متن کاملComparison of Photon and Electron Absorbed Fractions in Voxel-Based and Simplified Phantoms for Small Animals
Internal dosimetry on non-human biota is getting more important from the viewpoint of radiation protection of the environment. The International Commission on Radiological Protection (ICRP) proposed the Reference Animals and Plants using simplified phantoms, such as ellipsoids and spheres, and assessed absorbed fractions (AFs) for the whole bodies. In this study, photon and electron AFs in whol...
متن کاملestimation of photon specific absorbed fractions in digimouse voxel phantom using monte carlo simulation code fluka
background: most preclinical studies are carried out on mice. for internal dose assessment of a mouse, specific absorbed fraction (saf) values play an important role. in most studies, saf values are estimated using older standard human organ compositions and values for limited source target pairs. objective: saf values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 ke...
متن کاملEvaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA
Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...
متن کاملEstimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
BACKGROUND Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs. OBJECTIVE SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 2012
ISSN: 0033-8303,1884-4111
DOI: 10.3769/radioisotopes.61.315