Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction
A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...
متن کاملExtraction and Determination of Heavy Metals Using Silver Coated Magnetic Nanoparticles and Flame Atomic Absorption Spectrometry
A rapid, simple and sensitive magnetic solid phase extraction (MSPE) method was developed for the pre-concentration and determination of copper and cadmium ions. In this study, modified Fe3O4@Ag nanoparticles were synthesized and then ligand 2-isonicotinoyl hydrazine carbodithiolate (ITHCDT) was bonded to silver due to the formation of covalent bond of S-Ag. In this method, copper and cadmium i...
متن کاملdetermination of trace copper(ii) in food samples by flame atomic absorption spectrometry after cloud point extraction
a new method for the determination of trace copper(ii) in food samples by cloud point extraction(cpe) combined with flame atomic absorption spectrometry(faas) is presented and evaluated. the method is based on the fact that hydrophobic complex of copper(ii) with sodium diethyldithiocarbamate (ddtc) was formed at ph 6.0 and subsequently the hydrophobic complex was extracted into surfactant-rich ...
متن کاملMetastable aqueous foams and flame atomic absorption spectrometry.
Using calmagite as the compleximetric agent in spectro-photometric measurements of magnesium in serum involves a nonspecific matrix effect, which may bias results by as much as 25 to 30% if aqueous standards are used in serum assays. We have overcome this effect by simply adding 5 pL of the amphoteric detergent Empigen BB (300 g/L; Albright and Wilson Ltd., Whitehaven, U.K.) to each reaction cu...
متن کاملDetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...