Application of the Reassigned Smoothed Pseudo Wigner-Ville Distribution in Gear Defect Diagnosis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ISAR Imaging of Moving Targets Based on Reassigned Smoothed Pseudo Wigner-Ville Distribution

High-range resolution inverse synthetic aperture radar (ISAR) imaging is a promising tool for non-cooperative target identification and has attracted wide interest within the scientific and military communities. Most of the existing ISAR algorithms are based on the Fourier transform. However, for long coherent integration time or for fast maneuvering targets, simple Fourier processing without c...

متن کامل

seismic attenuation coefficient estimation using smoothed pseudo wigner-ville distribution

elastic energy of seismic wave is lost through propagation into the earth. various factors affect seismic energy. some of them are frequency independent and recovered in processing steps. but other factors such as intrinsic absorption of medium are frequency dependent and cannot be recovered by processing methods. lost energy caused by these factors is called attenuation. there are various meth...

متن کامل

Detection of the valvular split within the second heart sound using the reassigned smoothed pseudo Wigner–Ville distribution

BACKGROUND In this paper, we developed a novel algorithm to detect the valvular split between the aortic and pulmonary components in the second heart sound which is a valuable medical information. METHODS The algorithm is based on the Reassigned smoothed pseudo Wigner-Ville distribution which is a modified time-frequency distribution of the Wigner-Ville distribution. A preprocessing amplitude...

متن کامل

A Comparison of HRV Techniques: The Lomb Periodogram versus The Smoothed Pseudo Wigner-Ville Distribution

The purpose of a tachogram (from the Greek tachos, speed) is to quantify changes in heart rate over short time periods, ordinarily less than one day. Typically, the heart's rate of contraction is sampled once per beat (and hence unevenly in time), being taken as the inverse of the interval which occurs between consecutive QRS complexes (known as an RR interval). Since the Fourier transform algo...

متن کامل

A New Method for Interference Reduction in the Smoothed Pseudo Wigner-Ville Distribution

This article presents a new method facilitating interference reduction in the Wigner-Ville distribution, which is used for nonstationary signal analysis, for example in machine condition monitoring. The algorithm is based on multiple Smoothed Pseudo Wigner-Ville distributions: differently smoothed time-frequency planes are compared and, for every point, a cross-term free value is calculated on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Mapta Journal of Mechanical and Industrial Engineering (MJMIE)

سال: 2021

ISSN: 2517-4258

DOI: 10.33544/mjmie.v4i2.148