Are day-to-day variations of airborne particles associated with emergency ambulance dispatches?
نویسندگان
چکیده
منابع مشابه
stability and attraction domains of traffic equilibria in day-to-day dynamical system formulation
در این پژوهش مسئله واگذاری ترافیک را از دید سیستم های دینامیکی فرمول بندی می کنیم.فرض کرده ایم که همه فاکتورهای وابسته در طول زمان ثابت باشند و تعادل کاربر را از طریق فرایند منظم روزبه روز پیگیری کنیم.دینامیک ترافیک توسط یک نگاشت بازگشتی نشان داده می شود که تکامل سیستم در طول زمان را نشان می دهد.پایداری تعادل و دامنه جذب را توسط مطالعه ویژگی های توپولوژیکی تکامل سیستم تجزیه و تحلیل می کنیم.پاید...
Patients arriving by ambulance to the Emergency Department; vital signs and 30 day mortality
Background Vital signs outside the normal range on arrival to an emergency department are related to a poor prognostic outcome. However, the knowledge of the prognostic value of vital signs measured in the ambulance is scarce. The aim of the study was to describe vital signs measured in the ambulance (saturation, systolic blood pressure, pulse, respiratory frequency and Glasgow Coma Scale (GCS)...
متن کاملImpact of short-term exposure to fine particulate matter on emergency ambulance dispatches in Japan.
BACKGROUND Evidence of an association between fine particulate matter (PM2.5) and morbidity is limited in Asia. We used a case-crossover design to evaluate the association between short-term exposure to PM2.5 and emergency ambulance dispatches (as a proxy of acute health outcomes), and to calculate the extent to which a 10 μg/m(3) decrease in PM2.5 concentrations would reduce the number of ambu...
متن کاملShort communication:Ecological larval fish groups in Chabahar Bay in relation to day/night and monsoon variations
این مقاله فاقد چکیده میباشد.
متن کاملDay to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
PURPOSE To evaluate the variations of multi-lumen balloon (MLB)-based brachytherapy from simulation day to treatment day and their dosimetric impacts during accelerated partial breast irradiation (APBI). MATERIAL AND METHODS A total of 42 CT images scanned from seven patients were evaluated with regards to daily variation due to of: 1) internal uncertainty: size and shape of balloon, seroma v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Occupational and Environmental Health
سال: 2013
ISSN: 1077-3525,2049-3967
DOI: 10.1179/2049396713y.0000000045