Arthroscopy Assisted 2 Cannulated Screw Fixation for Transverse Glenoid Fracture: A Case Report
نویسندگان
چکیده
منابع مشابه
Arthroscopic Removal of a Displaced Cannulated Screw after Glenoid Rim Fracture - A Case Report
INTRODUCTION Internal fixation has been shown to successfully prevent recurrent dislocations after fractures of the glenoid rim. With regards to fixation either suture anchors or screws can be used, depending on the fragment size. Complications regarding suture anchors and their management have been described previously but not the arthroscopic management of screw impingement. CASE REPORT We ...
متن کاملArthroscopy-Assisted Reduction and Fixation of a Transversal Glenoid Fracture: About a Case
An articular glenoid fracture is an uncommon injury. Usually significantly displaced intra-articular glenoid fractures are treated with open reduction surgery. Conventional open surgery techniques involve high morbidity. Here we describe an arthroscopy-assisted reduction and fixation method of an Ideberg type III glenoid fracture. This method provides good articular reduction without extensive ...
متن کاملArthroscopy Assisted Percutaneous Fixation of Ideberg Type Iii Glenoid Fractures
INTRODUCTION Intra-articular glenoid fractures are extremely rare and may be associated with other injuries. Traditionally open reduction and internal fixation has been recommended in displaced intra-articular glenoid fractures. However open reduction is difficult and it may not be possible to address the associated intra-articular soft tissue injuries. A few reports of arthroscopic assisted fi...
متن کاملClinical and radiological outcomes of arthroscopically assisted cannulated screw fixation for tibial eminence fracture in children and adolescents
BACKGROUND The purpose of this study was to determine the efficacy and complications of arthroscopically assisted reduction and fixation with cannulated screws for tibial eminence fracture in skeletally immature patients. METHODS This was a retrospective case series study. Forty-eight patients who were skeletally immature at the time of tibial eminence fracture were treated in a tertiary chil...
متن کاملCannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
Purpose. To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. Methods. 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55o and 63o (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinics in Shoulder and Elbow
سال: 2016
ISSN: 2383-8337
DOI: 10.5397/cise.2016.19.2.105