Artifact-less coded aperture imaging in the x-ray band with multiple different random patterns
نویسندگان
چکیده
منابع مشابه
Pencil beam coded aperture x-ray scatter imaging
We use coded aperture x-ray scatter imaging to interrogate scattering targets with a pencil beam. Observations from a single x-ray exposure of a flat-panel scintillation detector are used to simultaneously determine the along-beam positions and momentum transfer profiles of two crystalline powders (NaCl and Al). The system operates with a 3 cm range resolution and a momentum transfer resolution...
متن کاملGrid-enhanced X-ray coded aperture microscopy with polycapillary optics
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imagin...
متن کاملA coded-aperture technique allowing x-ray phase contrast imaging with conventional sources
Phase contrast imaging PCI solves the basic limitation of x-ray imaging, i.e., poor image contrast resulting from small absorption differences. Up to now, it has been mostly limited to synchrotron radiation facilities, due to the stringent requirements on the x-ray source and detectors, and only one technique was shown to provide PCI images with conventional sources but with limits in practical...
متن کاملCompressive coded aperture imaging
Nonlinear image reconstruction based upon sparse representations of images has recently received widespread attention with the emerging framework of compressed sensing (CS). This theory indicates that, when feasible, judicious selection of the type of distortion induced by measurement systems may dramatically improve our ability to perform image reconstruction. However, applying compressed sens...
متن کاملIn situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an oblique angle. The imaging model represents the instrument as a linear system whose impulse response t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Astronomical Telescopes, Instruments, and Systems
سال: 2020
ISSN: 2329-4124
DOI: 10.1117/1.jatis.6.3.035002