Assessing intracranial vascular compliance using dynamic arterial spin labeling

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing intracranial vascular compliance using dynamic arterial spin labeling

Vascular compliance (VC) is an important marker for a number of cardiovascular diseases and dementia, which is typically assessed in the central and peripheral arteries indirectly by quantifying pulse wave velocity (PWV), and/or pulse pressure waveform. To date, very few methods are available for the quantification of intracranial VC. In the present study, a novel MRI technique for in-vivo asse...

متن کامل

Perfusion imaging using dynamic arterial spin labeling (DASL).

Recently, a technique based on arterial spin labeling, called dynamic arterial spin labeling (DASL (Magn Reson Med 1999;41:299-308)), has been introduced to measure simultaneously the transit time of the labeled blood from the labeling plane to the exchange site, the longitudinal relaxation time of the tissue, and the perfusion of the tissue. This technique relies on the measurement of the tiss...

متن کامل

Intracranial Dural Arteriovenous Fistula: Preliminary Report of Arterial Spin Labeling

Purpose: We report the results of applying arterial spin labeling (ASL) to intracranial dural arteriovenous fistula (DAVF). Methods: Sixteen patients with angiographically confirmed DAVF underwent ASL on a clinical 1.5 T or 3 T MR system. ASL was performed by Q2TIPS (second version of quantitative imaging of perfusion by using a single subtraction MRI pulse sequence with thin-slice TI1 periodic...

متن کامل

Selective Arterial Spin Labeling After Extra-Intracranial Bypass Surgery

Introduction: Arterial spin labeling (ASL) [1] is an important technique for the diagnosis of neurological diseases. Perfusion originating from the summed supply of all brain feeding arteries is commonly assessed. However, tagging single arteries is of interest to get additional information, e.g. efficiency estimation of a bypass surgery. One single artery is tagged to non-invasively determine ...

متن کامل

Perfusion imaging using arterial spin labeling.

Arterial spin labeling is a magnetic resonance method for the measurement of cerebral blood flow. In its simplest form, the perfusion contrast in the images gathered by this technique comes from the subtraction of two successively acquired images: one with, and one without, proximal labeling of arterial water spins after a small delay time. Over the last decade, the method has moved from the ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: NeuroImage

سال: 2016

ISSN: 1053-8119

DOI: 10.1016/j.neuroimage.2015.09.008