Assessment of cellular beams with transverse stiffeners and closely spaced web openings

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steel Beams with Web Openings

The responsibility of a Structural Engineer lies in not merely designing the structure based on safety and serviceability considerations but he also has to consider the functional requirements based on the use to which the structure is intended. While designing a power plant structure or a multi-storeyed building, the traditional structural steel framing consists of beams and girders with solid...

متن کامل

Design of composite beams with web openings

ao"length of opening dh, dl"distance from top of steel section to centroid of concrete force at high and low moment ends of the opening, respectively dr"distance from outside edge of flange to centroid of reinforcement *b"maximum bending deflection for unperforated beam *m,b"maximum bending deflection for a member with an opening Fy"yield stress of steel FM y"reduced axial strength of steel in ...

متن کامل

Shear Strength of Reinforced Web Openings in Steel Beams

The floor beams of steel buildings, cold-formed steel floor joists in particular, often require large web openings, which may affect their shear capacities. A cost effective way to mitigate the detrimental effects of such openings is to weld/fasten reinforcements. A difficulty associated with an experimental investigation to establish suitable reinforcement schemes for openings in shear zone is...

متن کامل

Design Requirements for Plate Girders with Bolted Transverse Stiffeners

The web of plate girders in bridges are usually reinforced by welded transverse stiffeners in order to improve their shear capacity.Due to problems associated with field welding and fatigue, welded stiffeners are not suitable for retrofitting existing bridges. Bolted stiffeners are a practical alternative for strengthening girders that are expected to experience shear stress in excess of their ...

متن کامل

Closely spaced saccades.

The relationships between saccadic velocity, duration, and magnitude have been used to prove the normalcy of saccades with intersaccadic intervals of less than 200 ms. Pairs of normal saccades with small intersaccadic intervals will have the second saccade larger or smaller and going in the same or the opposite direction than the first saccade. These normal saccades may be horizontal, vertical,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thin-Walled Structures

سال: 2015

ISSN: 0263-8231

DOI: 10.1016/j.tws.2015.05.005