ASSESSMENT OF DIAPHRAGMATIC FUNCTION PARAMETERS BY INTENSIVE CARE ULTRASOUND COMPARED TO CONVENTIONAL PARAMETERS DURING SPONTANEOUS BREATHING TRIAL
نویسندگان
چکیده
منابع مشابه
Assessment of diaphragmatic function parameters by intensive care ultrasound compared to conventional parameters during spontaneous breathing trial
Methods This is a prospective observational study conducted between June 2013 and November 2013 in intensive care unit patients planned to wean with spontaneous breathing trial. After 1-hour of T-piece trial, the patient’s RSBI, TV, VC and NIP were recorded. By ultrasound, we measured the amplitude of diaphragmatic movement (ADM), time to the maximum amplitude (TTMA), and the diaphragmatic thic...
متن کاملTo: Behavior of lung ultrasound findings during spontaneous breathing trial
The new century brought a “new” kid on the block to the field of intensive care. Ultrasound (US) came from the radiology departments, and it has renewed intensive care medicine. Focused on the critical care patient and with the intensivist as a performer, US has set a new paradigm for medicine. Due to its increasing relevance, in 2009,(1) the American College of Chest Physicians and La Société ...
متن کاملBehavior of lung ultrasound findings during spontaneous breathing trial
OBJECTIVE We aimed to investigate a potential association between B-lines and weaning failure. METHODS Fifty-seven subjects eligible for ventilation liberation were enrolled. Patients with tracheostomy were excluded. Lung ultrasound assessments of six thoracic zones were performed immediately before and at the exnd of the spontaneous breathing trial. B-predominance was defined as any profile ...
متن کاملinvestigation of effective parameters on the rigidity of light composite diaphragms (psscb) by fem
در این رساله با معرفی سقف های psscb متشکل از ترکیب ورق های فولادی ذوزنقه ای و تخته های سیمانی الیافی به عنوان سقف های پیش ساخته (سازگار با سیستم سازه ای قاب های فولادی سبک) به بررسی پارامترهای موثر بر صلبیت سقف، پرداخته می شود. در تحقیق حاضر ابتدا به مدل سازی دو نمونه سقف آزمایش شده، به روش اجزاء محدود با استفاده از نرم افزار تحلیلی abaqus ver 6.10 پرداخته شده است. نمونه های ساخته شده تحت اعما...
Spirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis
Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50 pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Intensive Care Medicine Experimental
سال: 2015
ISSN: 2197-425X
DOI: 10.1186/2197-425x-3-s1-a1004