Asymmetric Etalon Effect in Fold-Type Optical Feedback Cavity-Enhanced Absorption Spectroscopy

نویسندگان

چکیده

To further improve the performance of cavity-enhanced spectroscopy systems, a high-quality U-cavity system was established. In process experiment, an asymmetric ripple effect, which is different from previous etalon found, seriously affects spectral system. This unique phenomenon mainly manifests in amplitudes fluctuations curves measured by folding mirror and end Based on multi-beam interference theory, we analyzed characteristics transmission spectrum each presence effect at mirror, obtained following conclusions: for system, strength inversely proportional to its loss value, that is, larger loss, smaller spectrum, vice versa. order eliminate this most effective way caused light feedback mirror. After improving minimum detectable absorption coefficient αmin=8.33×10−9cm−1 with U-shape Optical Feedback Cavity-Enhanced Absorption Spectroscopy. These works are valuable references design folded Spectroscopy systems have potential laser wavelength calibration measurement mirror’s reflectance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical-feedback cavity-enhanced absorption spectroscopy with a quantum cascade laser.

Optical-feedback cavity-enhanced absorption spectroscopy is demonstrated in the mid-IR by using a quantum cascade laser (emitting at 4.46 μm). The laser linewidth reduction and frequency locking by selective optical feedback from the resonant cavity field turns out to be particularly advantageous in this spectral range: It allows strong cavity transmission, which compensates for low light sensi...

متن کامل

Cavity-enhanced absorption spectroscopy of molecular oxygen

A high-finesse optical cavity was employed to perform highly sensitive spectroscopy of molecular oxygen at wavelengths near 763 nm. An equivalent absorption length of ;1 km was obtained by a 26-cm-long optical cavity with a finesse of 6000. An extended cavity diode laser was frequency locked to the cavity, and pure absorption profiles were recovered by monitoring of the cavity transmission duri...

متن کامل

Cavity-enhanced spectroscopy in optical fibers.

Cavity-enhanced methods have been extended to fiber optics by use of fiber Bragg gratings (FBGs) as reflectors. High-finesse fiber cavities were fabricated from FBGs made in both germanium/boron-co-doped photosensitive fiber and hydrogen-loaded Corning SMF-28 fiber. Optical losses in these cavities were determined from the measured Fabry-Perot transmission spectra and cavity ring-down spectrosc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2022

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app121910031