Atom beam velocity measurements using phase choppers
نویسندگان
چکیده
منابع مشابه
Atom beam velocity measurements using phase choppers
We describe a new method to measure atom beam velocity in an atom interferometer using phase choppers. Phase choppers are analogous to mechanical chopping discs, but rather than being transmitted or blocked by mechanical choppers, an atom receives different differential phase shifts (e.g. zero or π radians) from phase choppers. Phase choppers yield 0.1% uncertainty measurements of beam velocity...
متن کاملDYE JET VELOCITY DISTRIBUTION MEASUREMENTS USING PHOTOTHERMAL DEFLECTION SPECTROSCOPY
We demonstrate that photothermal deflection spectroscopy can be used to measure velocity distributions in dye jets. Such measurements are useful in determining the quality of flow in dye jets, The quality of jets is very important for a stable and naanow linewidth operation of dye lasers
متن کاملTriplet-phase measurements using reference-beam X-ray diffraction.
Reference-beam diffraction (RBD) is a recently developed phase-sensitive X-ray diffraction technique that incorporates the principle of multiple-beam diffraction into the standard oscillating-crystal data-collection method [Shen (1998). Phys. Rev. Lett. 80, 3268-3271]. Using this technique, a large number of multiple-beam interference profiles can be recorded simultaneously on an area detector,...
متن کاملRight ventricular (RV) velocity measurements using high resolution spiral myocardial phase velocity mapping (PVM)
Background PVM is capable of accurately and reproducibly measuring myocardial velocities in the LV [1]. However, analyzing RV motion is more difficult because of the thinness of the free wall and its asymmetrical geometry. Currently, the most commonly used technique for assessing RV velocities and function is Tissue Doppler Imaging (TDI) where the high temporal resolution allows the detailed an...
متن کاملOptimization of beam-flow angles for Doppler ultrasound flow velocity measurements using slanted gel pads.
The aim of this study was to assess whether slanted gel pads can be used to optimize beam-flow angles and flow velocity measurements for Doppler ultrasound. The right carotid artery of a single healthy female volunteer was measured alternatively five times without and with an 18° angled slanted gel pad between the ultrasound transducer and skin by 13 radiologists. Beam-flow angles and peak syst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: New Journal of Physics
سال: 2011
ISSN: 1367-2630