Atomic torsional modal analysis for high-resolution proteins
نویسندگان
چکیده
منابع مشابه
Atomic torsional modal analysis for high-resolution proteins.
We introduce a formulation for normal mode analyses of globular proteins that significantly improves on an earlier one-parameter formulation [M. M. Tirion, Phys. Rev. Lett. 77, 1905 (1996)] that characterized the slow modes associated with protein data bank structures. Here we develop that empirical potential function that is minimized at the outset to include two features essential to reproduc...
متن کاملHigh-resolution modal analysis
Usual modal analysis techniques are based on the Fourier transform. Due to the ∆T.∆f limitation, they perform poorly when the modal overlap μ exceeds 30%. A technique based on a high-resolution analysis algorithm and an order-detection method is presented here, with the aim of filling the gap between the lowand the high-frequency domains (30% < μ < 100%). A pseudo-impulse force is applied at po...
متن کاملHigh-resolution nanomechanical analysis of suspended electrospun silk fibers with the torsional harmonic atomic force microscope
Atomic force microscopes have become indispensable tools for mechanical characterization of nanoscale and submicron structures. However, materials with complex geometries, such as electrospun fiber networks used for tissue scaffolds, still pose challenges due to the influence of tension and bending modulus on the response of the suspended structures. Here we report mechanical measurements on el...
متن کاملTorsional Resonance Mode Imaging for High- Speed Atomic Force Microscopy
The instrumentation of high-speed imaging has been a challenge for scanning probe-based technologies. Mechanical stability of the system, surface tracking at sharp topographic transitions and prolonging tip lifetime have been the determining factors for practical applications. In this paper we report a new type of feedback control based on the torsional resonance amplitude (TRmode ) of cantilev...
متن کاملTorsional MEMS scanner design for high-resolution display systems
In scanning display systems, high horizontal and vertical resolution, and high refresh rate requirements translate into large mirror-size scan-angle product and high scanner-frequency requirements. A comparison between published scan-angle mirror-size product values for MEMS scanners and a Steel mechanical scanner is presented. Current performance levels of Steel mechanical scanners are better;...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review E
سال: 2015
ISSN: 1539-3755,1550-2376
DOI: 10.1103/physreve.91.032712