Automated bacterial identification by angle resolved dark-field imaging
نویسندگان
چکیده
منابع مشابه
Variable-angle high-angle annular dark-field imaging: application to three-dimensional dopant atom profiling
Variable-angle high-angle annular dark-field (HAADF) imaging in scanning transmission electron microscopy is developed for precise and accurate determination of three-dimensional (3D) dopant atom configurations. Gd-doped SrTiO3 films containing Sr columns containing zero, one, or two Gd dopant atoms are imaged in HAADF mode using two different collection angles. Variable-angle HAADF significant...
متن کاملAngle Resolved TEM Imaging of Pt Nanoparticles
Particle shape and size are two of the most important characteristics of nanoparticulate catalysts that determined their activity and selectivity. In many studies, the shapes of nanoparticles are characterized using transmission electron micrographs obtained at a single nanoparticle orientation and thus, the shape determination is based on viewing a single cross-sectional profile of the nanopar...
متن کاملX-ray Dark Field Imaging
A new kind of enhanced contrast X-ray imaging of weakly absorbing materials in dark field mode is presented. Samples such as plastics and biological tissue are a perpetual challenge for radiographic imaging. Recent innovative approaches such as Diffraction Enhanced Imaging (DEI), “phase contrast”, grating interferometry (Talbot-Lau), or Refraction Enhanced Imaging (REI) have in common that they...
متن کاملExamination of bacterial flagellation by dark-field microscopy.
A method is described for visualizing unstained bacterial flagella by dark-field light microscopy. Since individual filaments can be seen, a genus such as Salmonella, which is peritrichously flagellated, can readily be distinguished from a polarly flagellated genus such as Pseudomonas. Polarly flagellated bacteria generally swim much faster than peritrichously flagellated bacteria, and turn by ...
متن کاملPtychographic electron microscopy using high-angle dark-field scattering for sub-nanometre resolution imaging
Diffractive imaging, in which image-forming optics are replaced by an inverse computation using scattered intensity data, could, in principle, realize wavelength-scale resolution in a transmission electron microscope. However, to date all implementations of this approach have suffered from various experimental restrictions. Here we demonstrate a form of diffractive imaging that unshackles the i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biomedical Optics Express
سال: 2013
ISSN: 2156-7085,2156-7085
DOI: 10.1364/boe.4.001692