Automated Shape Adjustment of Interlocking Joints for Structurally Informed Design of Masonry Block Assemblages

نویسندگان

چکیده

This paper introduces a tool to design structurally informed assemblages of interlocking blocks. First, the static problem limit analysis is extended with openings and running bond pattern. Then, method measure assemblage infeasibility due sliding resistance violation (namely infeasibility) described. An optimization procedure finally presented minimise measured by automatically changing shape joints.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Homogenization of Interlocking Masonry Walls

In a previous publication the authors proposed a continuous model for describing the mechanical behaviour of ‘Running Bond’ masonry walls. Here a different masonry structure is considered. This structure is ‘bi-atomic’ in the sense that its pattern consists in two kind of blocks with different. The homogenization by differential expansions technique is used for obtaining an equivalent Cosserat ...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

Behaviour of Masonry Wall Constructed using Interlocking Soil Cement Bricks

According to the masonry standard the compressive strength is basically dependent on factors such as the mortar strength and the relative values of unit and mortar strength. However interlocking brick has none or less use of mortar. Therefore there is a need to investigate the behavior of masonry walls using interlocking bricks. In this study a series of tests have been conducted; physical prop...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP conference series

سال: 2021

ISSN: ['1757-899X', '1757-8981']

DOI: https://doi.org/10.1088/1757-899x/1044/1/012006