Automatic Current-Constrained Double Loop ADRC for Electro-Hydrostatic Actuator Based on Singular Perturbation Theory

نویسندگان

چکیده

For an electro-hydrostatic actuator (EHA), the position, speed, and current cascade three-loop control architecture are dominant in existing active disturbance rejection (ADRC). However, this suffers from many problems, such as severe noise sensitivity of extended state observer (ESO), excessive complexity structure, too tuned parameters, which makes controller not easy to implement practice. Aiming at above drawbacks, a novel double-loop ADRC strategy that is automatic current-constrained proposed, whole simplified position integrated speed–current architecture. Firstly, for loop, singular perturbation theory used reasonably reduce order model subsystem EHA. A reduced (ROADRC) synthesized, only effectively reduces ESO, but also circumvents use actuation acceleration information design process. Secondly, designed by taking speed subsystems EHA into synthesis, avoids problem loop bandwidth conventional architecture, number parameters significantly reduced. Additionally, uncomplicated effective (CACADRC) solve cannot be automatically constrained. Finally, comparing PI with traditional ADRC, detailed simulation analysis carried out verify effectiveness merits proposed controller. The results show inherits advantages high precision strong performance can efficiently decrease ESO achieve control.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Robust Position Control of Electro-hydrostatic Actuator Systems

In this paper, an adaptive PID sliding mode controller is proposed for the position control of electro-hydrostatic actuator(EHA) systems with system uncertainties and saturation in the motor. An EHA prototype is developed and system modeling and parameter identification are executed. Then, adaptive PID sliding mode controller and optimal anti-windup PID controller are designed and the performan...

متن کامل

Singular perturbation theory

When we apply the steady-state approximation (SSA) in chemical kinetics, we typically argue that some of the intermediates are highly reactive, so that they are removed as fast as they are made. We then set the corresponding rates of change to zero. What we are saying is not that these rates are identically zero, of course, but that they are much smaller than the other rates of reaction. The st...

متن کامل

Development of friction free controller for electro-hydrostatic actuator using feedback modulator and disturbance observer

Hydraulic actuators have high power-to-weight ratios, making them suitable for high-power robotic applications such as in walking robots and construction machines. However, large frictional forces in hydraulic actuators, rotary hydraulic actuators in particular, degrade the control performance. To suppress frictional forces and increase robustness against modeling errors, this study considered ...

متن کامل

Singular constrained linear systems

In the linear system Ax = b the points x are sometimes constrained to lie in a given subspace S of column space of A. Drazin inverse for any singular or nonsingular matrix, exist and is unique. In this paper, the singular consistent or inconsistent constrained linear systems are introduced and the effect of Drazin inverse in solving such systems is investigated. Constrained linear system arise ...

متن کامل