Automatic pressure calibration system for pressure sensors
نویسندگان
چکیده
منابع مشابه
Mathematical modelling to support traceable dynamic calibration of pressure sensors
This paper focuses on the mathematical modelling required to support the development of new primary standard systems for traceable calibration of dynamic pressure sensors. We address two fundamentally different approaches to realising primary standards, specifically the shock tube method and the drop-weight method. Focusing on the shock tube method, the paper presents first results of system id...
متن کاملDynamic calibration of pressure sensors - French metrology special feature
Pressure measurement in non-equilibrium conditions is required in many applications. For example, pressure must be monitored in the cylinders of an engine to study combustion phenomena, in an injection moulding press to study a moulding process, in a Pitot tube to determine the speed of an aircraft, or in a catheter to determine blood pressure. In applications like these the pressure quantity i...
متن کاملInexpensive and Automatic Calibration for Acceleration Sensors
In this paper, we present two methods for calibration of acceleration sensors that are inexpensive, in-situ, require minimum user interaction and are targeted to a broad set of acceleration sensor applications and devices. We overcome the necessity of orthogonal axes alignment by extending existing calibration methods with a non-orthogonal axes model. Our non-orthogonal method can furthermore b...
متن کاملDesign and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention
Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...
متن کاملA system for arterial and venous pressure calibration and recording.
(1) Complete sterility must be maintained. (2) All the connecting tubes and the pressure transducers must be filled with liquid before they are attached to the patient. (3) Intermittent flushing of the tubes must be possible, preferably by syringe, without danger to the transducer. (4) Calibration by the application of known pressures to the transducers must be possible without having to discon...
متن کاملذخیره در منابع من