Availability of Alternative Liquid Scintillator for Tritiated Water Measurements
نویسندگان
چکیده
منابع مشابه
Development of a liquid scintillator-based 3D detector for range measurements of spot-scanned proton beams
The goal of the present study is to develop a liquid scintillator-based 3D detector and investigate its performance for beam range measurements in real time. The detector design consists of a tank filled with water-equivalent liquid scintillator that scintillates in response to incident proton beams. Three scientific complementary metal-oxide semiconductor (sCMOS) cameras collect the resulting ...
متن کاملConsideration of Water Productivity for Farm Water Management in Different Conditions of Water Availability for Dominant Summer Crops
ABSTRACT- Efficient use of irrigation water for summer crops should be considered seriously due to rare occurrence of precipitation in summer. This research was focused on the assessment of water use efficiency for dominant crops of summer cropping pattern in the study area (i.e., maize and rice) via considering water productivity (WP) with different water management scenarios at farm level at ...
متن کاملPhotosynthate transport using tritiated water.
The exchange of HTO with aerial portions of the soybean was studied under a variety of conditions. When fed to a lone leaf or leaflet in a saturated air atmosphere (all other leaves and the growing point having been excised), the HTO profile virtually ceases at a distance of 2 cm from the feeding chamber in the photosynthetic plant, but is greater and more extensive in the unilluminated plant. ...
متن کاملAntineutrino geophysics with liquid scintillator detectors
Detecting the antineutrinos emitted by the decay of radioactive elements in the mantle and crust could provide a direct measurement of the total abundance of uranium and thorium in the Earth. In calculating the antineutrino flux at specific sites, the local geology of the crust and the background from the world’s nuclear power reactors are important considerations. Employing a global crustal ma...
متن کاملRadioassay of Low Specific Activity Tritiated Water by Improved Liquid Scintillation Techniques
THE liquid scintillation technique has achieved considerable popularity as a radioassay method for tritiated water because it combines ease of sample preparation with adequate counting efficiency. However, for low specific activity samples, i.e. samples producing a count approaching that of background, counting times become long and the advantages of the technique become marginal. The purpose o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 2012
ISSN: 0033-8303,1884-4111
DOI: 10.3769/radioisotopes.61.179