Back-up Perlindungan Relay Jarak Zona Kedua oleh Directional Overcurrent Relays dengan Combined Curves
نویسندگان
چکیده
منابع مشابه
A Novel Objective Function for Directional Overcurrent Relays Coordination
Directional overcurrent relays (DOCRs) are widely used to protect power systems. For optimal coordination of DOCRs, several techniques have been proposed to solve this problem. A common way of optimal coordination of DOCRs is using evolutionary algorithms such as genetic algorithm (GA). In this paper, a novel strategy for DOCRs coordination is proposed. In the proposed strategy, a new objective...
متن کاملDirectional Overcurrent Relays Coordination Problems in Distributed Generation Systems
This paper proposes a new approach to the distributed generation system protection coordination based on directional overcurrent protections with inverse-time characteristics. The key question of protection coordination is the determination of correct values of all inverse-time characteristics coefficients. The coefficients must be correctly chosen considering the sufficiently short tripping ti...
متن کاملEfficient Dimensionality Reduction of Directional Overcurrent Relays Optimal Coordination Problem
Directional over current relays (DOCR) are commonly used in power system protection as a primary protection in distribution and sub-transmission electrical systems and as a secondary protection in transmission systems. Coordination of protective relays is necessary to obtain selective tripping. In this paper, an approach for efficiency reduction of DOCRs nonlinear optimum coordination (OC) is p...
متن کاملSolving Directional Overcurrent Relay Coordination Problem Using Artificial Bees Colony
This paper presents the implementation of Artificial Bees Colony (ABC) algorithm in solving Directional OverCurrent Relays (DOCRs) coordination problem for near-end faults occurring in fixed network topology. The coordination optimization of DOCRs is formulated as linear programming (LP) problem. The objective function is introduced to minimize the operating time of the associated relay which d...
متن کاملConsidering Pilot Protection in the Optimal Coordination of Distance and Directional Overcurrent Relays
The aim of the relay coordination is that protection systems detect and isolate the faulted part as fast and selective as possible. On the other hand, in order to reduce the fault clearing time, distance protection relays are usually equipped with pilot protection schemes. Such schemes can be considered in the distance and directional overcurrent relays (D&DOCRs) coordination to achieve faster ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jurnal Teknik ITS
سال: 2017
ISSN: 2337-3539,2301-9271
DOI: 10.12962/j23373539.v5i2.16078