Based on laser energy absorption ratio differential algorithm methane concentration detection system
نویسندگان
چکیده
To reduce the interference of other gases and improve detection accuracy in CH 4 concentration detection, a system is proposed, ratio differential algorithm designed. The difference value absorbed light intensity between chamber 1 2 used to suppress calculation by component gases. high gas 3 obtain accurate position characteristic absorption peak, it applied as boundary condition for data extraction 1. Two sets calculations were used, one set was calculate laser energy at absorption, Then, proportion coefficients two values inversion function using this structure. interfering include C H 6 , SO CO . A total 1,000 sample collected mixed gas, with 400 rest test samples. results show that about times traditional algorithm. modeling time approximately 1/4 methods. It has certain advantages detecting environments
منابع مشابه
A novel methane detection system based on InGaAsP distributed feedback laser
The authors report a novel methane detection system based on InGaAsP DFB (distributed feedback) laser using the WMS-2f (wavelength modulation spectroscopy) to prompt the sensitivities of TDLAS (tunable diode laser absorption spectroscopy) measurement technology at the R(3) transition of the 2ν 3 band of methane. The system employs a novel signal processing to cancel emitter-amplitude variations...
متن کاملStabilized master laser system for differential absorption lidar.
Wavelength accuracy and stability are key requirements for differential absorption lidar (DIAL). We present a control and timing design for the dual-stabilized cw master lasers in a pulsed master-oscillator power-amplifier configuration, which forms a robust low-cost water-vapor DIAL transmitter system. This design operates at 823 nm for water-vapor spectroscopy using Fabry-Perot-type laser dio...
متن کاملImproved low concentration gas detection system based on intracavity fiber laser.
The improvement of a low concentration gas detection system based on the intracavity fiber laser is proposed in this paper. The sensitivity of the system is deduced based on Lambert-Beer law. The optimized system was established with the gas cell made elaborately. In order to apply the wavelength sweeping technique, the fiber Bragg grating reflector was substituted by the wavelength independent...
متن کاملA Fall Detection System based on the Type II Fuzzy Logic and Multi-Objective PSO Algorithm
The Elderly health is an important and noticeable issue; since these people are priceless resources of experience in the society. Elderly adults are more likely to be severely injured or to die following falls. Hence, fast detection of such incidents may even lead to saving the life of the injured person. Several techniques have been proposed lately for the fall detection of people, mostly cate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Frontiers in Physics
سال: 2023
ISSN: ['2296-424X']
DOI: https://doi.org/10.3389/fphy.2023.1223755