Bat algorithm for optimization of reinforced concrete columns

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rehabilitation of Reinforced Concrete Columns

In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...

متن کامل

Seismic Response of Reinforced Concrete Columns

There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...

متن کامل

OPTIMUM DESIGN OF REINFORCED CONCRETE FRAMES USING BAT META-HEURISTIC ALGORITHM

The main aim of the present study is to achieve optimum design of reinforced concrete (RC) plane moment frames using bat algorithm (BA) which is a newly developed meta-heuristic optimization algorithm based on the echolocation behaviour of bats. The objective function is the total cost of the frame and the design constraints are checked during the optimization process based on ACI 318-08 code. ...

متن کامل

Fragility Curves for Reinforced Concrete Frames with Lap-Spliced Columns

Placing column lap-splice in the locations of possible nonlinear deformation may adversely affect the structures response to strong ground motions. Localization of damage in splice zone may change the structural response and prevent the load redistribution and development of a uniform pattern of nonlinear excursions among the various members. Validated by existing laboratory experiments, this s...

متن کامل

Reinforced Concrete Columns in Torsion (RESEARCH NOTE).

ACT does not suggest any regulations for columns under torsion. However, by all means, the number of such columns used in steel and concrete structures is abundant. In this paper, using the results of laboratory tests on 35 square and rectangular columns with intermediate slender ratios, relations for determination of torsional strengths of reinforced concrete under axial compression have been ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PAMM

سال: 2016

ISSN: 1617-7061

DOI: 10.1002/pamm.201610329