Benefits of monitoring blood glucose by collection of blood on filter paper strips

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collection of blood on filter paper for measurement of glycated hemoglobin by affinity chromatography.

We present data on a filter-paper collection and assay method for measurement of glycated hemoglobin (gHb). Onto filter paper dipped into a solution of glucose oxidase (EC 1.1.3.4) and allowed to dry, approximately 20 microL of capillary blood was spotted. For analysis, we eluted the dried blood spot from the paper by soaking in water for 1 h, then measured the gHb in the eluate by affinity chr...

متن کامل

Benefits and limitations of self-monitoring of blood glucose.

Self-monitoring of blood glucose (SMBG) provides significant benefits to patients with diabetes and their healthcare providers. SMBG is increasingly recognized as an integral part of intensive therapy for all forms of diabetes. This article discusses the clinical utility of SMBG in type 1 (T1DM) and type 2 diabetes (T2DM) and looks at the relationship between SMBG and improved overall glycemic ...

متن کامل

Determination of glucose levels using dried filter paper blood spots: new perspective in home monitoring.

We present a method for the determination of blood glucose using dried filter paper blood spots. To validate this method, we compared our results using filter paper and simultaneously collected venous blood. We demonstrated that there is a linear relationship between the filter paper glucose levels and those determined in whole blood (r = 0.98). There was no significant difference between the r...

متن کامل

Glucose estimated with a Beckman Glucose Analyzer 2 in spots of capillary blood on filter paper.

1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...

متن کامل

Non-Invasive Determination of Blood Glucose Levels by Optical Waveguide

Objective: Today, there are various non-invasive techniques available for the determination of blood glucose levels. In this study, the level of blood glucose was determined by developing a new device using near-infrared (NIR) wavelength, glass optical waveguide, and the phenomenon of evanescent waves. Materials and Methods: The body's interstitial fluid has made possible the development of ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Practical Diabetes International

سال: 2002

ISSN: 1357-8170,1528-252X

DOI: 10.1002/pdi.345