BIPHASIC TRUNCATED EXPONENTIAL WAVEFORM IS SUPERIOR COMPARED TO PULSED BIPHASIC WAVEFORM IN CARDIOVERTING ATRIAL FIBRILLATION AND ATRIAL FLUTTER: A RANDOMIZED CONTROLLED TRIAL

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biphasic versus monophasic shock waveform for conversion of atrial fibrillation.

Cardioversion of atrial fibrillation (AF) using traditional monophasic shock waveform is unsuccessful in up to 20% of cases, and often requires several shocks of up to 360 J. Based on the success with biphasic shock waveform in converting ventricular fibrillation, it was postulated that biphasic shocks would allow cardioversion with lower energy. In a international multicenter, double-blind, ra...

متن کامل

Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform.

BACKGROUND We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. METHODS AND RESULTS Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasi...

متن کامل

Cardioversion Efficacy Using Pulsed Biphasic or Biphasic Truncated Exponential Waveforms: A Randomized Clinical Trial

BACKGROUND Several different defibrillators are currently used for cardioversion and defibrillation of cardiac arrhythmias. The efficacy of a novel pulsed biphasic (PB) waveform has not been compared to other biphasic waveforms. Accordingly, this study aims to compare the efficacy and safety of PB shocks with biphasic truncated exponential (BTE) shocks in patients undergoing cardioversion of at...

متن کامل

Biphasic waveform shocks were effective and efficient for cardioversion of atrial fibrillation.

I n t e r v e n t i o n Patients were allocated to impedance-compensated truncated exponential biphasic shocks (n = 96) or damped sine wave monophasic shocks (n = 107). Patients received up to 5 shocks: 100 joules (J), 150 J, 200 J, a fourth shock at maximum output for the initial waveform (200 J biphasic, 360 J monophasic), and a final crossover at maximum output of the alternate waveform. M a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 2015

ISSN: 0735-1097

DOI: 10.1016/s0735-1097(15)60354-0