Bis-dimethylaminobenzaldehyde Schiff-Base Cobalt(II) Complex as a Neutral Carrier for a Highly Selective Iodide Electrode

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Binuclear Schiff base complex of manganese(III) as a neutral carrier for a highly selective iodide electrode.

A new highly selective iodide electrode incorporating a binuclear manganese(III) complex, bis(salicylaldehyde-aminopropanol)dichloroaceticdimanganese(III) [Mn(III)(2)-BSAPDCA], as a neutral carrier is described. The electrode displays an anti-Hofmeister selectivity sequence: iodide >> perchlorate > salicylate > thiocyanate > nitrate > bromide > nitrite > chloride > sulfate. The excellent select...

متن کامل

Highly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex

In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of  for perchlorate. The lim...

متن کامل

Perchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier.

A synthesized bis(dibenzoylmethanato)Co(II) complex (Co(DBM)(2)), has been used as a ionophore for the preparation of a new perchlorate ion-selective electrode. The electrode exhibits a Nernstian response over the perchlorate concentration range of 8.0x10(-7)-1.0x10(-1)M with a slope of 60.3+/-0.5 mV per decade of concentration. The limit of detection as determined from the intersection of the ...

متن کامل

(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies

A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...

متن کامل

highly selective perchlorate membrane electrode based on synthesized schiff base complex

in this work we introduce a practical use of synthesized schiff base metal complex in sensing application. a new perchlorate-selective electrode based on the complex n, n'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (ii) [cul] as the membrane carrier was developed. the electrode exhibits a good  nernstian slope of -55.0 ± 1.0 mv/decade and a linear range of  for perchlorate. the limit o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2004

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.20.1661