BISTRO: An outer-volume suppression method that tolerates RF field inhomogeneity
نویسندگان
چکیده
منابع مشابه
Reduced field of view MRI with rapid, B1-robust outer volume suppression.
MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of intere...
متن کاملBISTRO: An Efficient Relaxation-Based Method for Contextual Bandits
We present efficient algorithms for the problem of contextual bandits with i.i.d. covariates, an arbitrary sequence of rewards, and an arbitrary class of policies. Our algorithm BISTRO requires d calls to the empirical risk minimization (ERM) oracle per round, where d is the number of actions. The method uses unlabeled data to make the problem computationally simple. When the ERM problem itself...
متن کاملOptimized Outer Volume Suppression for Slice Selective MRSI
A. Henning, M. Schär, R. F. Schulte, K. P. Pruessmann, P. Boesiger Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Kanton Zurich, Switzerland, John Hopkins University, Baltimore, MD, United States Introduction In spite of significantly improved saturation pulses [1,2] sufficient outer volume (OVS) and especially fat suppression in MRSI could only be achieved in combinat...
متن کاملRF inhomogeneity compensation in structural brain imaging.
Three-dimensional T(1)-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with centric phase encoding (PE) in the inner loop provide structural brain images with a high spatial resolution and high tissue contrast. A disadvantage of this sequence type is the susceptibility to inhomogeneities of the radiofrequency (RF) coil, which may result in poor image contrast in some per...
متن کاملkT-PINS RF Pulses for Low-Power Field Inhomogeneity-Compensated Multislice Excitation
kT-PINS RF Pulses for Low-Power Field Inhomogeneity-Compensated Multislice Excitation Anuj Sharma, Samantha Holdsworth, Rafael O'Halloran, Eric Aboussouan, Anh Tu Van, Julian Maclaren, Murat Aksoy, V Andrew Stenger, Roland Bammer, and William A Grissom Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, United States, Radiology, Stanford University, Stanford, California, United...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2001
ISSN: 0740-3194
DOI: 10.1002/mrm.1144