Boiling heat transfer on a fine horizontal wire in refrigerant-oil mixtures.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations

Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...

متن کامل

Experiments on Flow Boiling Heat Transfer of Pure CO2 and CO2-Oil Mixtures in Horizontal Smooth and Micro-Fin Tubes

Experiments on the flow boiling heat transfer of almost pure CO2 and CO2-oil mixtures in horizontal smooth and micro-fin tubes have been carried out. The smooth tube is a stainless steel tube with an inside diameter of 3mm, and the micro-fin tube is a copper tube with a mean inside diameter of 3.04mm. Experiments were carried out at mass velocities from 190 to 1300kg/(ms), saturation temperatur...

متن کامل

Flow Boiling Heat Transfer of Binary Mixtures HFO1234yf/R32 in a Smooth Horizontal Tube

HFO1234yf is a promising alternative for automobile air conditioners because of its low GWP of 4 and thermophysical properties similar to those of R134a. However, its performance is inferior to R410A. This makes it difficult to be applied to residential air-conditioners. A mixture of HFO1234yf and R32 is expected to balance both the GWP and COP requirement when applied to residential air-condit...

متن کامل

In Tube Evaporation Heat Transfer of Refrigerant Mixtures

Heat transfer coefficient data was taken during in-tube evaporation of five differenct refrigerant mixtures. These measurements were performed in a 318" O.D. (9.7 mm) smooth copper tube at refrigerant temperatures of -zoe and 4°C. Four different mass fluxes ranging from 125 to 375 kg/s-m2 were tested. On a mass basis, the five different mixtures tested were: R-125 (40%) I R-32 (60%), R-32 (30%)...

متن کامل

experimental investigation in pool boiling heat transfer of pure/binary mixtures and heat transfer correlations

nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. in this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in pure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B

سال: 1986

ISSN: 0387-5016,1884-8346

DOI: 10.1299/kikaib.52.1793