Bond strength of concrete confined by SMA wire jackets
نویسندگان
چکیده
منابع مشابه
Compressive Strength of Confined Concrete in CCFST Columns
This paper presents a new model for predicting the compressive strength of steel-confined concrete on circular concrete filled steel tube (CCFST) stub columns under axial loading condition based on Artificial Neural Networks (ANNs) by using a large wide of experimental investigations. The input parameters were selected based on past studies such as outer diameter of column, compressive strength...
متن کاملEffect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes
In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...
متن کاملBond of Reinforcement in High-Strength Concrete
This paper describes an examination of the development of tension lap splices in high-strength concrete and the applicability of the restriction in the ACI 318 code where the values of √fc′ used to calculate development length shall not exceed 100 psi. The focus is on the development of splices with Grade 60 epoxy-coated and uncoated bars in normalweight concrete. A summary of the behavior of b...
متن کاملCompressive Strength Prediction by ANN Formulation Approach for FRP Confined Rectangular Concrete Columns
Enhancement of strength and ductility is the main reason for the extensive use of FRP (fiber reinforced polymer) jackets to provide external confinement to reinforced concrete columns especially in seismic areas. Therefore, numerous researches have been carried out in order to provide a better description of the behavior of FRP confined concrete for practical design purposes. This study present...
متن کاملBond of High Strength Concrete with High Strength Reinforcing Steel
This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics Procedia
سال: 2010
ISSN: 1875-3892
DOI: 10.1016/j.phpro.2010.11.100