Bonding Strength between Al–Wires and Ni–P Plated Lead Frames
نویسندگان
چکیده
منابع مشابه
Stannylplumbylenes: bonding between tetravalent tin and divalent lead.
Depending on stoichiometry, reactions of the mixed valence Sn(0)/Sn(III) compound Sn(SnAr(3))(2) (1) (Ar = C(6)H(4)(O(i)Pr)(2)-2,6) with the likewise substituted plumbylene PbAr(2) (3) afforded either the homoleptic distannylplumbylene Pb(SnAr(3))(2) (4) or the heteroleptic arylstannylplumbylene Pb(Ar)SnAr(3) (5), a valence isomer of a stannaplumbene.
متن کاملSome relationship between G-frames and frames
In this paper we proved that every g-Riesz basis for Hilbert space $H$ with respect to $K$ by adding a condition is a Riesz basis for Hilbert $B(K)$-module $B(H,K)$. This is an extension of [A. Askarizadeh, M. A. Dehghan, {em G-frames as special frames}, Turk. J. Math., 35, (2011) 1-11]. Also, we derived similar results for g-orthonormal and orthogonal bases. Some relationships between dual fra...
متن کاملCorrelation between antioxidant activity and bonding strength on bleached enamel
Objective: This study used the 2,2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH) method to evaluate the percentage of antioxidant activity (%AA) of green tea (GT) and sodium ascorbate (SA) gel in three concentrations (10%, 20% and 30%), and the influence of these concentrations on the microshear bond strength (μ-SBT) values of bleached enamel, using 10% carbamide peroxide (CP). Materials and method...
متن کاملUltimate Collapse Strength Assessment of Damaged Steel Plated Grillages
Across many industries damage events leading to a breach in structural integrity continue to occur. An area where this can lead to particularly unsafe conditions is in the maritime environment, where it may be difficult to rescue crew and cargo. In order to improve structural safety through design for the survivability or to assess the residual strength of a damaged vessel in an emergency respo...
متن کاملUltimate Collapse Strength Assessment of Damaged Steel-Plated Structures
In an unpredictable world where human intervention or unexpected environmental conditions can prevail, damage can occur to manmade structures. Whilst structural design allows for redundancy, or a structural capability beyond the general working load of the structure, it is necessary to be able to analyse and understand the residual capability of a damaged structure to ensure the safety of perso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materials Transactions, JIM
سال: 1993
ISSN: 0916-1821,2432-471X
DOI: 10.2320/matertrans1989.34.976