Bow-tie wobble artifact: Effect of source assembly motion on cone-beam CT
نویسندگان
چکیده
منابع مشابه
Artifact analysis of approximate helical cone-beam CT reconstruction algorithms.
In this paper, four approximate cone-beam CT reconstruction algorithms are compared: Advanced single slice rebinning (ASSR) as a representative of algorithms employing a two dimensional approximation, PI, PI-SLANT, and 3-PI which all use a proper three dimensional back-projection. A detailed analysis of the image artifacts produced by these techniques shows that aliasing in the z-direction is t...
متن کاملComparing CT Reconstruction Algorithms Regarding Cone–Beam Artifact Performance
Purpose: With increasing cone angle the cone– beam artifacts in x–ray CT become more and more prominent. It is well known that cone–beam CT (CBCT) does not satisfy the data completeness condition for exact image reconstruction and therefore allows only for approximate image reconstruction [1]. Additionally, in clinical C–arm CT often only a short scan with less than a full rotation can be acqui...
متن کاملIterative image-domain ring artifact removal in cone-beam CT.
Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain variations using flat-panel detectors, and may lead to structured non-uniformities and deterioration of image quality. The purpose of this study is to propose a method of general ring artifact removal in CBCT images. This method is based on the polar coordinate system, where the ring artifacts manifest as str...
متن کاملThe Social Bow Tie
Understanding tie strength in social networks, and the factors that influence it, have received much attention in a myriad of disciplines for decades. Several models incorporating indicators of tie strength have been proposed and used to quantify relationships in social networks, and a standard set of structural network metrics have been applied to predominantly online social media sites to pre...
متن کاملOn-the-Fly Motion-Compensated Cone-Beam CT Using an a Priori Motion Model
Respiratory motion causes artifacts in slow-rotating cone-beam (CB) computed tomography (CT) images acquired for example for image guidance of radiotherapy. Respiration-correlated CBCT has been proposed to correct for the respiratory motion, but the use of a subset of the CB projections to reconstruct each frame of the 4D CBCT image limits their quality, thus requiring a longer acquisition time...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2011
ISSN: 0094-2405
DOI: 10.1118/1.3582944