Breast Cancer: Computer-aided Detection with Digital Breast Tomosynthesis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection

PowerLook® Tomo Detection, a concurrent computer-aided detection (CAD) system for digital breast tomosynthesis (DBT) developed by iCAD, Inc., Nashua, NH, was tested to determine if the software can shorten the reading time of DBT without affecting radiologist interpretation or performance. The results of this study showed a 29.2% average reduction in reading time (up to 36.5% reduction) with th...

متن کامل

Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis

We propose computer-aided detection (CADe) algorithm for microcalcification (MC) clusters in reconstructed digital breast tomosynthesis (DBT) images. The algorithm consists of prescreening, MC detection, clustering, and false-positive (FP) reduction steps. The DBT images containing the MC-like objects were enhanced by a multiscale Hessian-based three-dimensional (3D) objectness response functio...

متن کامل

Computer-aided detection of clustered microcalcifications in digital breast tomosynthesis: a 3D approach.

PURPOSE To design a computer-aided detection (CADe) system for clustered microcalcifications in reconstructed digital breast tomosynthesis (DBT) volumes and to perform a preliminary evaluation of the CADe system. METHODS IRB approval and informed consent were obtained in this study. A data set of two-view DBT of 72 breasts containing microcalcification clusters was collected from 72 subjects ...

متن کامل

Computer-aided detection system for breast masses on digital tomosynthesis mammograms: preliminary experience.

The purpose of the study was to design a computer-aided detection (CAD) system for breast mass detection on digital breast tomosynthesis (DBT) mammograms and to perform a preliminary evaluation of the performance of this system. Twenty-six patients were imaged with a prototype DBT system. Institutional review board approval and written informed patient consent were obtained. Use of the data set...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiology

سال: 2015

ISSN: 0033-8419,1527-1315

DOI: 10.1148/radiol.2015141959