Bronchial dosimeter for radon progeny.

A true bronchial dosimeter has been designed, consisting of four 400-mesh wire screens and a filter paper. With a face velocity of 3.3 cm s(-1) for home exposure and 4.6 cm s(-1) for mine exposure, the deposition pattern on the wire screens were found to satisfactorily match the variation of the dose conversion factor (in units of mSv WL M(-1)) with the size of radon progeny from 1 to 1000 nm. ...

متن کامل

Bronchial dosimeters for radon progeny for Chinese males and females.

Bronchial dosimeters have been designed for adult Chinese males and females for home and mine exposures, which can give the bronchial doses from radon progeny by direct measurements. The bronchial dosimeter for home exposures consists of five 400-mesh wire screens. With a sampling face velocity of 3.3 cm s(-1) for Chinese males and 2.7 cm s(-1) for Chinese females, the deposition pattern on the...

متن کامل

Integrating Radon Progeny Monitor

INTRODUCTION The Japan Nuclear Cycle Development Institute (JNC) carried out research and development projects related to uranium exploration in Japan from 1967 to 1987. Several mining facilities have been retained after the end of projects. Hence, the study on the behavior and the environmental impact of radon and its progeny from the mining facilities is being continued at the Ningyo-toge Env...

متن کامل

Diurnal variation of radon progeny.

The diurnal variation of the gross alpha (alpha) radioactivity in the air near the ground and the gamma (gamma) radioactivity emitted from the ground have been monitored in North-eastern Greece. Meteorological information comprising air temperature and humidity has been simultaneously recorded. Over a period of the 24h of a typical day, the variation of alpha-radioactivity reaches a peak in the...

متن کامل

Bronchial allergen challenge using the Medicaid dosimeter.

BACKGROUND Bronchial allergen provocations are well established in asthma research. We evaluated the reproducibility of single-concentration, single-step allergen challenges in volunteers with grass pollen allergy. METHODS Forty-seven subjects underwent bronchial challenges using the aerosol provocation system nebulizer (Medicaid Sidestream) with incremental doses of grass pollen to define th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Radiation and Isotopes

سال: 2001

ISSN: 0969-8043

DOI: 10.1016/s0969-8043(01)00117-8