Calculating ISQ Primary Stability of a Dental Implant through Micromotion

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

PURPOSE This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS Two different types of bone (type 1 and type 2) ...

متن کامل

Micromotion of Dental Implants: Basic Mechanical Considerations

Micromotion of dental implants may interfere with the process of osseointegration. Using three different types of virtual biomechanical models, varying contact types between implant and bone were simulated, and implant deformation, bone deformation, and stress at the implant-bone interface were recorded under an axial load of 200 N, which reflects a common biting force. Without friction between...

متن کامل

Primary stability of a shoulderless Zweymüller hip stem: a comparative in vitro micromotion study

BACKGROUND The Zweymüller stem design has proven long-term stability with a 20-year survival rate of over 90 %. Primary stability necessitates implant-bone micromotions below 150 μm, otherwise bony ingrowth is negatively influenced. METHODS Using fresh paired human femurs, we investigated a modification of the Zweymüller-type stem design with reduced proximal lateral shoulder in reference to ...

متن کامل

Updated secondary implant stability data of two dental implant systems. A retrospective cohort study

BACKGROUND At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. MATERIAL AND METHODS Secondary implant stability data based on both RFA and MM measurements were collected and ana...

متن کامل

Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.

BACKGROUND Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. PATIENTS AND METHODS Seventy patients with complete mandibular edentulism underwent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Periodica Polytechnica Mechanical Engineering

سال: 2019

ISSN: 1587-379X,0324-6051

DOI: 10.3311/ppme.14192