Calculation and Validation of Continuous Pulse Transit Time Based on Normalized Pulse Wave Velocity
نویسندگان
چکیده
منابع مشابه
Pulse Wave Analysis and Pulse Wave Velocity
momanometer that provides arterial pressures (brachial systolic and diastolic pressure) is coming under question. The concerns extend well beyond the familiar issue of “white coat” hypertension, home and 24-h blood pressure recordings, and the phase-out of mercury based instruments. These concerns relate to the inaccuracy of all cuff devices for measuring pressure within the brachial artery, th...
متن کاملValidation of Distensibility Measurements from MRI-based Pulse Wave Velocity
Introduction: The use of Fourier-velocity-encoding(FVE) M-mode MRI to measure pulse wave velocity (PWV) in arteries has great potential in determining vessel health as PWV provides an indirect measure of distensibility [1]. Previous reports have shown compelling results indicating the utility of this method in vivo. However, the actual values of arterial compliance in vivo are generally unknown...
متن کاملPulse wave velocity measurement
The article deals with the investigation of pulse wave propagation in arteries. A part of work involves also design and realization of devices serving for scanning of pulse wave by reflective photoplethysmography. The work describes a use of microcontroller serving for data flow control, communication and analog signal digitalization using integrated analog to digital converter.
متن کاملPulse Transit Time Measuring
.............................................................................................2 Background......................................................................................................................3 Motivation............................................................................................6 Client Requirements....................................................
متن کاملMeasurement of aortic pulse wave velocity in CMR: comparison of transit time estimators
Background CMR is increasingly used for measuring aortic arch PWV (arch-PWV) by using accurate aortic length and transit time between flow waves. If robust aortic length measurement is an obvious strength of CMR thanks to many 3D imaging approaches available, Δt measurement remains a major challenge. Consequently, different methods have been previously described to estimate the Δt using CMR, bu...